Objective:
To analyze the effects of optical zone ablation diameter on LASIK-induced higher order optical aberrations in myopia.
Methods:
Four hundred and sixty-one eyes of 236 patients treated with LASIK for myopia were divided into high, moderate and low myopia group according to preoperative spherical equivalent diopter. In each group, eyes were divided into four subgroups according to optic zone ablation diameter. Before and after surgery 6 months, monochromatic wavefront aberrations of each eye were objectively measured using WASCA Analyzer Aberrometer. F test and q test were used to analyze the difference of total high order, horizontal coma, vertical coma, and spherical aberrations among four subgroups in each group at 4, 5, and 6 mm pupil size.
Results:
Before surgery no significant difference of higher order aberrations among four subgroups was found. After surgery, there was significant difference of total high order, and spherical aberrations among four subgroups. Total high order, and spherical aberrations in larger optical zone ablation diameter subgroup were significantly lower than that in smaller one. The difference was significant at 4, 5, and 6 mm pupil size in high myopia group, and 6 mm pupil size in low myopia group. At 6 mm pupil size, the difference was significant between each subgroup in high myopia group and subgroup I and subgroup IV in low myopia group. There was no significant difference of horizontal coma, and vertical coma aberrations among four subgroups.
Conclusions:
Optical zone ablation diameter has influence on LASIK-induced higher order optical aberrations. Larger optical zone can decrease total higher order and spherical aberrations after LASIK. The effects are more significant in high myopia group than in low myopia group.
Related Concept Videos
Focusing of Light in the Eye
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Angle Closure Glaucoma: Treatment
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview