Development of a harmonised method for the profiling of amphetamines: III. Development of the gas chromatographic
Kjell Andersson1, Kaisa Jalava, Eric Lock
1Swedish National Laboratory of Forensic Science-SKL, SE-581 94 Linköping, Sweden. kjell-b.andersson@skl.polisen.se
Abstract:
This study focused on gas chromatographic analysis of target compounds found in illicit amphetamine synthesised by the Leuckart reaction, reductive amination of benzyl methyl ketone, and the nitrostyrene route. The analytical method was investigated and optimised with respect to introduction of amphetamine samples into the gas chromatograph and separation and detection of the target substances. Sample introduction using split and splitless injection was tested at different injector temperatures, and their ability to transfer the target compounds to the GC column was evaluated using cold on column injection as a reference. Taking the results from both techniques into consideration a temperature of 250 degrees C was considered to be the best compromise. The most efficient separation was achieved with a DB-35MS capillary column (35% diphenyl 65% dimethyl silicone; 30 m x 0.25 mm, d(f) 0.25 microm) and an oven temperature program that started at 90 degrees C (1 min) and was increased by 8 degrees C/min to 300 degrees C (10 min). Reproducibility, repeatability, linearity, and limits of determination for the flame ionisation detector (FID), nitrogen phosphorous detector (NPD), and mass spectrometry (MS) in scan mode and selected ion monitoring (SIM) mode were evaluated. In addition, selectivity was studied applying FID and MS in both scan and SIM mode. It was found that reproducibility, repeatability, and limits of determination were similar for FID, NPD, and MS in scan mode. Moreover, the linearity was better when applying FID or NPD whereas the selectivity was better when utilising the MS. Finally, the introduction of target compounds to the GC column when applying injection volumes of 0.2 microl, 1 microl, 2 microl, and 4 microl with splitless injection respectively 1 microl with split injection (split ratio, 1:40) were compared. It was demonstrated that splitless injections of 1 microl, 2 microl, and 4 microl could be employed in the developed method, while split injection and splitless injections of 0.2 microl should be avoided.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Development of Analytical Methods
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...