Related Experiment Video
Updated: Jul 18, 2026

07:34
A Cost-effective and Reliable Method to Predict Mechanical Stress in Single-use and Standard Pumps
Published on: August 5, 2015
The case for the rope-pump in Africa: a comparative performance analysis
1Water, Engineering and Development Centre, Institute of Development Engineering, Loughborough University, Loughborough, LE11 3TU, UK. P.A.Harvey@lboro.ac.uk
Journal of Water and Health
|December 21, 2006
Summary
Locally manufactured rope-pumps offer a sustainable alternative to conventional handpumps for rural water supplies in sub-Saharan Africa. Contrary to fears, rope-pumps do not compromise water quality and outperform handpumps in most aspects.
Area of Science:
- Water resource engineering
- Public health
- Rural development
Background:
- Conventional handpumps are prevalent in rural sub-Saharan Africa but often fail due to maintenance issues.
- Locally manufactured rope-pumps are cheaper and easier to maintain but have faced skepticism regarding water quality.
Observation:
- A study in northern Ghana compared rope-pumps and conventional handpumps.
- Methods included user interviews, sanitary surveys, water quality analysis, and technical performance measurements.
Findings:
- Rope-pumps outperformed conventional handpumps on most performance metrics.
- No significant difference in microbiological water quality impact was observed between the two pump types.
Implications:
- Rope-pumps present a viable and sustainable technological solution for improving community water supplies across sub-Saharan Africa.
- Addressing maintenance capacity is crucial for long-term water supply sustainability.
Related Concept Videos
Pumped Concrete
Concrete in large quantities can be pumped across long distances for placing in inaccessible sites. This system comprises a hopper that receives concrete from a mixer, a pump to propel the concrete, and pipelines that facilitate its delivery.
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
ATP Driven Pumps I: An Overview
ATP-driven pumps, also known as transport ATPases, are integral membrane proteins. They have binding sites for ATP located on the membrane's cytosolic side and the ion-conducting domain in the transmembrane region. These pumps use the free energy released from ATP hydrolysis to move the solutes across cell membranes against an electrochemical gradient.
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and are...
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and are...
Application of the Energy Equation
The application of the energy equation to centrifugal pumps is a fundamental principle in fluid dynamics and engineering. In this scenario, the energy equation is used to calculate the flow rate of a centrifugal pump responsible for transferring water between two reservoirs at different elevations. The pump applies an energy input of 7500 joules per second, and the vertical difference between the lower and upper reservoirs is 10 meters. Additionally, the head loss due to friction and other...
ATP Driven Pumps II: P-type Pumps
The P-type pumps are a large family of integral membrane transporter ATPases. They are divided into five major types based on substrate specificity, from I to V.
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...

