Related Experiment Video
Updated: Jul 18, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Additional value of integrated PET-CT in the detection and characterization of lung metastases: correlation with CT
W De Wever1, L Meylaerts, L De Ceuninck
1Department of Radiology, University Hospitals Gasthuisberg, Herestraat 49, 3000 Leuven, Belgium. walter.dewever@uz.kuleuven.ac.be
Abstract:
The purpose was evaluating retrospectively the additional value of integrated positron emission tomography (PET) and computed tomography (CT) in the detection of pulmonary metastases in comparison with CT and PET alone. Fifty-six lung nodules, divided into three groups according their size, detected in 24 consecutive patients with a known primary tumor were retrospectively evaluated with integrated PET-CT, CT and PET. The nature of these nodules was determined by either histopathology or a follow-up of at least 6 months. The CT and PET images of the integrated PET-CT were evaluated separately by a radiologist and a nuclear medicine physician, the integrated PET-CT images were evaluated by a chest radiologist and nuclear medicine physician in consensus. The investigators were asked to search lung nodules and to determine whether these nodules were metastases or not. Sensitivity and accuracy for CT, PET and integrated PET-CT for characterization of all pulmonary nodules were, respectively: 100%, 90%, 100% and 57%, 55%, 55%. There was no significant difference in the characterization of pulmonary nodules between integrated PET-CT and CT alone (P=1.000) and PET alone (P=0.1306). An accurate evaluation is only possible for lesions larger than 1 cm.
More Related Videos
08:47Improved Visualization of Lung Metastases at Single Cell Resolution in Mice by Combined In-situ Perfusion of Lung Tissue and X-Gal Staining of lacZ-Tagged Tumor Cells
Published on: August 21, 2012
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET