Related Experiment Video
Updated: Jul 18, 2026

The Intra-Aortic Balloon Pump
Published on: February 5, 2021
Intra-aortic balloon counterpulsation in a patient with the failing Fontan circulation
Ujjwal K Chowdhury1, Shyam S Kothari, Ganapathy K Subramaniam
1Department of Cardiothoracic and Vascular Surgery, All India Institute of Medical Sciences, New Delhi, India. ujjwalchowdhury@gmail.com
Abstract:
We report a 23-year-old patient undergoing functionally univentricular repair who developed cardiac failure due primarily to systemic ventricular dysfunction. The failing Fontan circulation was successfully re-established using intra-aortic balloon counterpulsation. Aortic counterpulsation facilitates recovery of systemic ventricular function, and appears to be a reasonable alternative in select instances of cardiac failure in patients with the Fontan circulation.