Background:
Cardiac resynchronization therapy has been shown to be an effective treatment to improve functional status and prolong survival among patients with advanced congestive heart failure. However, as many as 30% of patients do not respond. Nonresponse may be due to suboptimal left ventricular lead placement. Studies have indicated that leads placed in the midlateral left ventricle (LV) wall usually result in improved dP/dT and increased pulse pressure, compared with other locations. When the surgeon is placing the leads thoracoscopically, however, in a chest with multiple adhesions, anatomic landmarks can be obscured. It is desirable to have an objective physiologic method to determine optimal lead placement. The optimal LV pacing site may be best determined by locating the site with the latest depolarization.
Methods:
A pacing lead attached to a pulse analyzer was introduced through a thoracoscopic port and used as a mapping electrode to electrically map exposed areas of the left ventricle. The right ventricular pacing lead was also attached to the pulse analyzer and the interval between the right ventricular pulse and the LV depolarization (paced depolarization interval) was measured in 19 patients undergoing thoracoscopic LV lead placement. A site with a paced depolarization interval less than 110 ms was not accepted.
Results:
Electrical mapping was possible in 19 of 29 consecutive patients in whom it was attempted. The most frequent reason for not mapping was the presence of extensive scarring. In 7 of 19 patients (36.8%) mapped, the site that would have been chosen by anatomic landmarks was not the site with the longest paced depolarization interval, and thus the lead placement was altered.
Conclusions:
The site with the longest paced depolarization interval is only selected 63.2% of the time when utilizing anatomic landmarks for placement. Nonresponse may be due to suboptimal LV lead placement. Measurement of paced depolarization intervals provides a physiologic method of determining optimal LV lead placement.
More Related Videos
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...