Related Experiment Video
Updated: Jul 18, 2026

Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Evaluation of arm and thigh circumference in screening low birth weight newborns
1Dept. of Preventive and Social Medicine, Govt. Medical College, Miraj. vinay_tapare@yahoo.co.in
The present cross-sectional study collected data regarding birth weight along with arm and thigh circumference of 174 consecutive newborns delivered at Maternity Hospital, Tasgaon during 2003. To compare & evaluate utility of arm & thigh circumferences for the detection of LBW newborns. Assessment of the best suitable measurement for identification of low birth weight newborns was made by comparison of Coefficient of Determinants (R(2)), Sensitivity and Specificity values and Kappa Statistics. The estimated cut off points of arm and thigh circumference for given value of birth weight 2.5 kg. were 9.1 cm and 14.2 cm. respectively. Although both measurements are highly sensitive, present study established supiriority of arm circumference over thigh circumference in predicting low birth weight newborns. Thigh circumference is more reliable. Advantages of these measurements are their simplicity & low cost.
The present cross-sectional study collected data regarding birth weight along with arm and thigh circumference of 174 consecutive newborns delivered at Maternity Hospital, Tasgaon during 2003. To compare & evaluate utility of arm & thigh circumferences for the detection of LBW newborns. Assessment of the best suitable measurement for identification of low birth weight newborns was made by comparison of Coefficient of Determinants (R(2)), Sensitivity and Specificity values and Kappa Statistics. The estimated cut off points of arm and thigh circumference for given value of birth weight 2.5 kg. were 9.1 cm and 14.2 cm. respectively. Although both measurements are highly sensitive, present study established supiriority of arm circumference over thigh circumference in predicting low birth weight newborns. Thigh circumference is more reliable. Advantages of these measurements are their simplicity & low cost.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessing Blood pressure in the Leg
Preparation:
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: