Related Experiment Video
Updated: Jul 18, 2026

Probing and Mapping Electrode Surfaces in Solid Oxide Fuel Cells
Published on: September 20, 2012
Simultaneous in situ reflectance and probe beam deflection measurements at solid electrode-aqueous electrolyte
Ping Shi1, Iosif Fromondi, Qingfang Shi
1Department of Chemistry, Case Western Reserve University, Cleveland, Ohio 44106-7078, USA.
Abstract:
A method is herein described for performing simultaneous in situ normal incidence reflectance spectroscopy (DeltaR/R, lambda = 633 nm) and probe beam deflection (PBD) measurements at solid electrodes in aqueous electrolytes, while scanning the potential linearly between two prescribed limits. Results obtained for Au in 0.1 M HClO4 and for Pt in both 0.1 M HClO4 and 0.1 M NaOH were found to be in excellent agreement with those reported in the literature for each individual spectroelectrochemical technique under otherwise similar conditions. Data collected for Pt electrodes in CO-saturated 0.1 M HClO4 revealed rather sudden changes in both DeltaR/R and PBD signals in the voltammetric region where the characteristic sharp peak associated with the oxidation of adsorbed CO occurs. This behavior was ascribed, respectively, to oxide formation (DeltaR/R) and to changes in the electrolyte composition in region neighboring the electrode, involving predominantly the acid concentration (PBD). In contrast, CO oxidation on Pt in 0.1 M NaOH yielded a PBD response consistent with formation of solution-phase carbonate via the reaction of the product, CO2, with hydroxyl ion. The exquisite sensitivity of DeltaR/R and PBD to interfacial phenomena was further illustrated using a monolayer of hemin irreversibly adsorbed on glassy carbon surfaces in 0.1 M Na2B4O7 (pH approximately 9.2). For this system, DeltaR/R was found to be proportional to the relative fractions of hemin and its reduced counterpart, while the PBD signal could be correlated with corresponding variations in the electrolyte concentration induced by the surface-bound redox process.
More Related Videos
09:36In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
Published on: September 12, 2018
08:31Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope (AFM-SECM)
Published on: February 10, 2021
Related Concept Videos
Interfacial Electrochemical Methods: Overview
Potentiometry: Membrane Electrodes
Electrochemical Systems
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Standard Electrode Potentials