Published on: December 1, 2023
Effect of composite temperature on in vitro intrapulpal temperature rise
Márcia Daronch1, Frederick A Rueggeberg, George Hall
1Department of Dental Materials, University of São Paulo, School of Dentistry, São Paulo, SP, Brazil. daronchny@yahoo.com
Summary
Pre-heating dental composite to 54 or 60 degrees C resulted in only a mild increase in intrapulpal temperature. The largest temperature rise during dental restoration occurred from the curing light, not the heated composite.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Restorative Dentistry
Background:
- Dental composite restorations are widely used.
- Material handling properties can be improved by pre-heating composites.
- Potential pulpal temperature increase is a concern with heated composites.
Purpose of the Study:
- To evaluate in vitro intrapulpal temperature changes during placement and restoration of dental composite.
- To compare temperature rise using room-temperature versus pre-heated composite (54°C and 60°C).
Main Methods:
- Human premolar Class V preparations were used with simulated pulp perfusion.
- Intrapulpal temperature was monitored using a thermocouple.
- Composite was placed at room temperature or pre-heated (54°C, 60°C) and light-cured.
Main Results:
- Pre-heated composite (54°C, 60°C) caused a statistically significant but mild increase in intrapulpal temperature (0.8°C).
- A significant temperature rise of 5°C was observed across all groups during photopolymerization.
- The curing light was the primary source of intrapulpal temperature increase.
Conclusions:
- Pre-heating dental composite to 54°C or 60°C does not significantly elevate intrapulpal temperatures in vitro.
- The photopolymerization stage poses a greater risk for intrapulpal temperature increase than using heated composite.
- Clinicians can consider using pre-heated composite without significant pulpal risk.
Related Concept Videos
Assessing Body Temperature - Oral
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Effect of Temperature Change on Reaction Rate
The Arrhenius equation,