Calculation of effective VV interval facilitates optimization of AV delay and VV interval in cardiac
Kevin Vernooy1, Xander A A M Verbeek, Richard N M Cornelussen
1Department of Physiology, Maastricht University, Maastricht, The Netherlands.
Background:
In hearts with left bundle branch block (LBBB), both atrioventricular (AV) delay and interventricular (VV) interval determine left ventricular (LV) pump function in cardiac resynchronization therapy (CRT). The optimal combination of AV delay and VV interval currently is determined by extensive hemodynamic testing.
Objectives:
The purpose of this study was to investigate whether the effective VV interval (VV(eff)) can be used to optimize AV delay and VV interval.
Methods:
In eight canine hearts with chronic LBBB, LV pacing was performed at various AV delays as well as biventricular pacing at multiple AV delays and VV intervals. LV pump function was assessed from LVdP/dt(max) and stroke volume (conductance catheter). Interventricular asynchrony was calculated from the timing difference between upslope of LV and RV pressure curves. VV(eff) was defined as the time delay between activation of the RV apex and LV lateral wall, irrespective of the source of RV activation (RV pacing or intrinsic conduction). VV(eff) was determined from pacemaker settings and surface ECGs recorded during biventricular pacing at various AV delays (positive values denote LV preexcitation).
Results:
For all animals, the relationship between VV(eff) and LVdP/dt(max) as well as LV stroke work was parabolic. Maximal improvement in LVdP/dt(max) was similar during LV pacing, simultaneous biventricular pacing, and sequential biventricular pacing and was obtained at similar values of VV(eff). VV(eff) was strongly correlated with interventricular asynchrony (R = 0.97 +/- 0.03). Optimum LVdP/dt(max) occurred at VV(eff) ranging from -24 to 12 ms (mean -6 +/- 13 ms). For each experiment, the optimal VV(eff) was virtually equal to the value halfway between its minimum (during LV pacing at short AV delay) and maximum (during LBBB) value (R = 0.91).
Conclusion:
Use of VV(eff) facilitates determination of the best combination of AV delay and VV interval during biventricular pacing. For each individual heart, VV(eff), resulting in optimum LV pump function, can be estimated using surface ECGs recorded during biventricular pacing.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Dysrhythmias VI: Management of Dysrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiomyopathy V: Interprofessional Care
Dysrhythmias V: Evaluating Dysrhythmias
Mitral Regurgitation III: Medical Management