Related Experiment Video
Updated: Jul 17, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
CT colonography: automatic measurement of polyp diameter compared with manual assessment - an in-vivo study
D Burling1, S Halligan, S A Taylor
1University College Hospital, London, UK.
Aim:
To investigate whether automated diameter assessment was feasible for CT colonography.
Materials And Methods:
Two experienced observers independently measured the maximum diameter of 50 polyps (colonoscopic reference size range 5-12 mm) from colonography datasets using conventionally placed software callipers and a variety of two-dimensional (2D) computed tomography (CT) window settings (colon, abdominal, bone, lung), and also three-dimensional (3D) perspective rendering. Polyps were also measured using automated polyp-segmentation software. Agreement between observers and with the colonoscopic reference measurement was determined using Bland-Altman, Wilcoxon, and Mann-Whitney U analyses.
Results:
Inter-observer agreement was similar for all window displays: mean difference in millimetres (SD difference; 95% limits of agreement) ranged from 0 (1.7, -3.3, 3.3) for 2D colon to -1.1mm (1.6, -4.3, 2.0) for 3D, compared with -0.5 (2.09, -4.6, 3.6) for automated measurement. When compared to colonoscopy, the largest discrepancy occurred using the 3D display (mean difference 1.3mm, 2.5mm for each observer). There was also a significant difference between estimates and reference size when using the 2D abdominal and 3D displays (p=0.03, <0.001).
Conclusion:
Automated polyp measurement is possible in vivo. Automated and conventional methods have comparable inter-observer agreement. The greatest measurement error is encountered when using a 3D display for estimates of diameter.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
