Related Experiment Video
Updated: Jan 2, 2026

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Estimating the uncertainty associated with Widmark's equation as commonly applied in forensic toxicology
1Washington State Patrol, Breath Test Section, 811 East Roanoke, Seattle, WA 98102, United States. rod.gullberg@wsp.wa.gov
Abstract:
No computation is performed more frequently by forensic toxicologists than that involving Widmark's equation. The equation is employed to estimate either the number of drinks consumed or the corresponding blood or breath alcohol concentration. Despite the wide use of Widmark's equation, rarely is an uncertainty estimate also provided. Estimates from Widmark's equation involve at least seven uncertain random variables. Uncertainty estimates are presented that rely on methods of general error propagation compared to a method developed by Widmark. Assuming reasonable variable and uncertainty estimates, the error propagation method yielded for N=10.4 drinks, a combined uncertainty (standard deviation) of 1.3 drinks (CV=12.3%). Similarly, estimating the blood alcohol concentration yielded for 0.120 g/100 ml, an uncertainty of 0.0255 g/100 ml (CV=21.2%). Widmark's uncertainty method yielded 1.6 drinks (CV=15.4%). The derivation of Widmark's uncertainty estimate is also presented, showing that he considered only rho and beta to be uncertain. Widmark estimates for the number of drinks should include a 2CV estimate of approximately 25% while the blood alcohol concentration estimate should include a 2CV estimate of approximately 42%. Including valid estimates of uncertainty should enhance the legal admissibility and confidence for Widmark estimations.
Related Concept Videos
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Propagation of Uncertainty from Systematic Error
Uncertainty: Overview
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...