Related Experiment Video
Updated: Jul 17, 2026

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
Published on: February 20, 2021
State-of-the-art dosimetric methods for internal and external exposures: conclusions of a EURADOS action
M A Lopez1, C M Castellani, L Currivan
1CIEMAT-Internal Dosimetry, Avda Complutene 22 28040 Madrid, Spain. ma.lopez@ciemat.es
Abstract:
In radiation protection dosimetry the quantity of interest is the effective dose (E); the dose limit to an adult worker applies to the sum of the relevant doses from external exposures and the relevant committed effective doses from intakes of radionuclides, during the same period of time. A EURADOS study was carried out to investigate how the results from personal dosemeters for external radiation, from workplace monitoring and from monitoring of internal exposures can be combined into a consistent system of individual monitoring. The integration of dosimetric methods and data for external and internal radiation require the complete characterisation of the occupational exposure present at the workplace, and the availability of adequate equipment and tools for the assessment of effective dose. To evaluate the capability of services to accomplish this approach, a European Dosimetry Network has been established among 28 European countries through the respective contact-persons and their dosimetric facilities which collaborated with EURADOS providing relevant data about performance and legal aspects. The information collected was presented as a monograph in Radiation Protection Dosimetry in 2004. The more relevant conclusions of this study are presented here.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Radiation: Applications
The average...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast, controlled...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...