Background:
Speckle tracking echocardiography (STE) has a unique feature of angle independence and, thus, may provide a powerful means of assessing left ventricular (LV) torsion (LVtor). The aims of this study were to assess: (1) the feasibility of 2-dimensional STE in the measurement of LVtor; and (2) the relationship of LVtor with age and conventional echocardiographic parameters.
Methods:
We consecutively recruited 160 healthy volunteers. After obtaining conventional echocardiographic parameters, apical and basal short-axis rotations were assessed with STE. LVtor was defined as the net difference between rotation angles in the two short-axis planes normalized for LV longitudinal length.
Results:
Reliable LVtor measurement was possible only in 56 volunteers (35%). This low feasibility was largely a result of the failure to obtain reliable basal rotation values. In 56 volunteers who were finally enrolled in this study, a significant correlation was found between LV ejection fraction and LVtor (r = 0.56, P < .001) and this correlation was attributed to apical (r = 0.47, P < .001) but not basal (P = .14) rotation. There was no significant change in LVtor with aging. However, initial counterclockwise motion (r = -0.51, P = .001) and its interval (r = -0.44, P = .001) in the basal rotation gradually decreased with aging, and correlated with early transmitral inflow velocity (r = 0.44 and 0.49, respectively) and its deceleration time (r = -0.43 and -0.48, respectively) (all P < .001). In contrast, such correlations were not found for initial clockwise motion and its interval in the apical rotation.
Conclusions:
Currently, STE has limited feasibility in the measurement of LVtor. There was no significant age-related change in LVtor. In LV rotations, basal rotation was affected by the age-related changes in the LV early diastolic filling, whereas apical rotation was mainly related to LV systolic performance.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...