Related Experiment Video
Updated: Jul 17, 2026

Intradermal Microdialysis: An Approach to Investigating Novel Mechanisms of Microvascular Dysfunction in Humans
Published on: July 21, 2023
Cold-induced vasodilatation is not homogenous or generalizable across the hand and feet
Stephen S Cheung1, Igor B Mekjavic
1Environmental Ergonomics Laboratory, School of Health and Human Performance, Dalhousie University, 6230 South St., Halifax, NS, B3H-3J5, Canada. stephen.cheung@dal.ca
Abstract:
Cold-induced vasodilatation (CIVD), a paradoxical cyclical increase in finger temperature upon cold exposure, is assumed to serve against cold injury. Most existing research has focused on hand and finger responses, yet most cold injuries occur in the feet. We investigated if CIVD responses of one finger can predict the responses of other fingers, and also whether the fingers could predict CIVD responses of the feet and toes. Ten subjects immersed their left hand up to the wrist in 8 degrees C water for 30 min. They passively rewarmed for 15 min, followed by immersion of the left foot to the ankle in 8 degrees C water for 30 min. Digit temperature at the edge of the nail bed was recorded on all fingers and toes and on the hand and feet. In all subjects, toe and foot temperature gradually decreased exponentially from approximately 31 to approximately 9 degrees C. No subject exhibited CIVD in any toe or on the foot itself. Eight subjects exhibited CIVD (>1 degrees C temperature increase) in at least one digit of the hand, but no consistent pattern existed in finger response to cold. No subject had strong (>2.0 degrees C) CIVD in all fingers. Five had strong CIVD in some but not all digits, with magnitudes ranging 1.4-7.5 degrees C, while three had weak (<2 degrees C) CIVD in some but not all digits. Four exhibited asynchronous CIVD in the fingers, with cycles beginning at different times. We conclude that CIVD is highly variable across the fingers, and is not a generalizable response across digits or limbs.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of blood...
Disorders of the Autonomic Nervous System
Raynaud's disease, also known as Raynaud's phenomenon, is a...
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...