Improved wrist pannus volume measurement from contrast-enhanced MRI in rheumatoid arthritis using shuffle transform

Emily Xanthopoulos1, Charles E Hutchinson, Judith E Adams

  • 1Imaging Science and Biomedical Engineering, University of Manchester, Manchester M13 9PT, UK.

Abstract

Insights

This study presents a reproducible method for measuring rheumatoid pannus in the hand using 3D contrast-enhanced MRI and shuffle transformation. This improved technique enhances visualization and quantitation of rheumatoid arthritis (RA) disease activity.

Area of Science:

  • Rheumatology
  • Radiology
  • Medical Imaging

Background:

  • Contrast-enhanced MRI aids in assessing rheumatoid pannus in the hand.
  • Quantifying rheumatoid pannus from MRI images presents challenges.

Purpose of the Study:

  • To develop and assess an improved method for measuring the volume of enhancing pannus (VEP) in the hands of rheumatoid arthritis (RA) patients.
  • Enhance the quantitation of rheumatoid pannus in RA hands.

Main Methods:

  • MR images of the hand and wrist were acquired from 14 RA patients over 13 weeks.
  • Volume of enhancing pannus (VEP) was calculated by subtracting precontrast from contrast-enhanced T1-weighted images.
  • Shuffle transformation technique, Maximum Intensity Projection (MIP), and 3D volume rendering were employed for pannus identification.

Main Results:

  • The shuffle transform significantly improved pannus visualization.
  • The within-subject coefficient of variation (CoV) was 0.13 between 0 and 1 week, with an estimated total CoV of 0.15.
  • No significant increase in variability was observed over the 13-week study period.

Conclusions:

  • 3D contrast-enhanced MRI combined with shuffle transform allows for reproducible measurement of VEP in rheumatoid hands.
  • This technique offers a reliable method for monitoring RA disease activity in the hand.