New coupling of planar chromatography with direct analysis in real time mass spectrometry
Gertrud Morlock1, Yoshihisa Ueda
1Institute of Food Chemistry, University of Hohenheim, Garbenstrasse 28, D-70599 Stuttgart, Germany. gmorlock@uni-hohenheim.de
Abstract:
The coupling of planar chromatography with direct analysis in real time time-of-flight mass spectrometry (DART-TOF-MS) was shown for the first time. Cutting the plate within a track led to substance zones positioned on the plate edge which were directly introduced into the DART gas stream. Mass signals were obtained instantaneously within seconds. Detectability was shown in the very low ng-range per zone on the example of isopropylthioxanthone. The coupling was perfectly suited for identification and qualitative purposes, but it was initially critical for quantification of results. Analytical response (R2 0.8202) and repeatability were strongly dependent from proper manual positioning of the HPTLC plate into the electronic or vibronic excited-state gas stream of the ion source. This drawback was overcome by using stable isotope-labeled standards shown on the example of caffeine. This way, analytical response (R2 0.9892) and repeatability (RSD < +/- 5.4%, n=6) were improved to a high extent. Spatial resolution by an in-house-built plate holder system was shown to be better than 3 mm. The decay of the signal was observed. The efficacy of this new coupling was compared to a plunger-based extraction device for HPTLC/electrospray ionisation-MS. The latter device showed detectability down to the pg-range, e.g. the limit of quantification for isopropylthioxanthone was found to be 100 pg. Repeatability was comparable (RSD +/- 6.7%), however, without the need of internal standard correction. Analytical response was slightly better and showed a determination coefficient R2 of 0.9983. Similar data were obtained for caffeine as well. Spatial resolution was 2 mm or 4 mm depending on the plunger head used. The comparison showed that HPTLC/DART-TOF-MS is a useful coupling method regarding qualitative aspects and it has the potential to cope also with the difficulties of quantification if isotope-labeled standards were used or if a plate holder system is employed as initially shown.
More Related Videos
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
High-Performance Liquid Chromatography: Types of Detectors