Objectives:
To review complications of indwelling tracheal stents and to describe a technique of stent removal using a combined open and endoscopic approach.
Design:
Descriptive case series.
Setting:
Medical University of South Carolina.
Patients:
Six patients were identified who had undergone combined open and endoscopic removal of indwelling tracheal stents. Coated (4 patients) and uncoated (2 patients) expandable metal stents had been present for an average time of 24 months (range, 5-60 months) before removal.
Main Outcome Measures:
Medical comorbidities, characteristics of the underlying airway lesion (origin, type, and length), stent characteristics (type and duration), and the presentation and management of stent-related complications.
Results:
All patients presented with worsening dyspnea and/or stridor, with 3 requiring intubation. Stent removal was performed in the operating room and consisted of initial exposure of the trachea for emergency airway access, removal of the indwelling stent under bronchoscopic and transtracheal guidance, and tracheotomy. Two patients experienced desaturations of more than 25% during the procedure, and 2 patients had stents that could be only partially removed. Five patients subsequently received Montgomery T-tubes without complications after a mean follow-up of 23 months (range, 6-40 months).
Conclusions:
Indwelling tracheal stents are becoming increasingly common in the management of benign airway stenosis. The stents frequently occlude with granulation tissue and may require removal. A combined open and endoscopic removal maximizes airway protection and minimizes potential complications.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...