The noise reductions provided by capsules consisting of uniform cylindrical shells whose two ends are closed off by like circular plates are analyzed for the low-frequency regime in which a capsule acts quasi-statically, much like a pressure vessel. The change in the confined volume is determined from the structural deflections produced by a net pressure difference, taking account of the interactions of the shell and end plates. Expressions for the noise reduction of a single capsule and of two nested capsules are derived. Some insights into the noise reduction effects of interaction between the shell and end plates are discussed, as are the contributions of these components.