[Security evaluation of subcutaneous injection with water-based dextran-coated magnetic fluid]
Yu Zhai1, Xiaoliang Wang, Xuman Wang
1Engineering Research Center for Nano Science and Technology, Shanghai Jiaotong University, Shanghai 200030, China. yzhai@sjtu.edu.cn
Abstract:
Water-based magnetic fluid was synthesized by using 50% dextran 40,000 as coated reagent. The acute toxicity and irritant of the magnetic fluid injected into mice subcutaneous tissues were examined. The lethal dosage 50 of dextran-coated magnetic fluid was 4409.61 +/- 514.93 mg/kg. Twenty four h after subcutaneous injecting with 30 mg/0.3 ml dextran-coated magnetic fluid, no more inflammation than hemangiectasia and leucocytes infiltration had been seen in subcutaneous tissues, 72 h later the reaction phenomena disappeared. While, injection with 30 mg/0.3 ml water-based oleate sodium-coated magnetic fluid, ulceration and break-off of cutis had been seen in the seventh days. That is to say, the dextran-coated magnetic fluid was safe and well tolerate, however, the oleate sodium-coated magnetic fluid was not fit to subcutaneous injection.