Related Experiment Video
Updated: Jul 17, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Validation and clinical application of time-frequency analysis of atrial fibrillation electrocardiograms
Daniela Husser1, Martin Stridh, David S Cannom
1Departments of Cardiology, Good Samaritan Hospital and Harbor-UCLA Medical Center, Los Angeles, California, USA.
Introduction:
Fibrillatory rates can reliably be obtained from surface ECGs during atrial fibrillation (AF) and correspond with right atrial (RA) and coronary sinus (CS) rates, while both the relation with pulmonary venous (PV) rates and determinants of fibrillatory waveform are unknown. Class III antiarrhythmic drugs prolong atrial refractoriness and decrease its dispersion, effects that may be reflected in ECG parameters. Consequently, this study sought (1) to investigate the relation between ECG fibrillatory rate and waveform characteristics with intraatrial/PV fibrillatory activity and (2) to noninvasively monitor class III antiarrhythmic drug effects in patients with AF.
Methods And Results:
Thirty-six patients with drug-refractory AF who underwent catheter-based pulmonary vein isolation and had AF at the beginning of the procedure were studied. A positive correlation between V1 rates obtained by time-frequency analysis and RA (R = 0.97, P < 0.001), CS (R = .71, P < 0.001), and PV rates (R = 0.65, P = 0.001) was found. Exponential decay defined as decay of the curve that connects power maxima of dominant and harmonic frequency components correlated with RA rate dispersion (R = 0.53, P = 0.004). In amiodarone-treated patients (n = 7), V1 rate (286 +/- 64 vs. 371 +/- 40 fpm, P < 0.001) and exponential decay (1.06 +/- 0.29 vs. 1.38 +/- 0.38, P = 0.034) were lower than in patients without amiodarone (n = 29). In 19 additional patients with persistent AF, oral dofetilide treatment decreased mean fibrillatory rate from 377 +/- 57 to 294 +/- 50 fpm (P < 0.001) and exponential decay from 1.24 +/- 0.43 to 0.85 +/- 0.22 (P = 0.002).
Conclusions:
Fibrillatory waves of surface ECG lead V1 closely reflect right atrial, and, to a lesser degree, left atrial activity. Time-frequency analysis allows noninvasive monitoring of antiarrhythmic drug effects on fibrillatory rate and waveform.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...