Related Experiment Video
Updated: Jul 17, 2026

Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
[Quantitative microbiological diagnostic method of intravascular catheters infection using the BacT/Alert SA bottles]
P Cermák1, P Sedláková, L Mejstríková
1Ustav klinické mikrobiologie, Univerzita Karlova v Praze, Lékarská fakulta v Hradci Králové, Fakultní nemocnice Hradec Králové. cermakp@lfhk.cuni.cz
Objective:
The study describes a method of quantitatively examining vascular catheters with the aid of hemocultural devices BacT/Alert.
Material And Methods:
The amount of bacteria present on the surface of the vascular catheters was determined based on the time to detection (TTD) in hemocultural vials inoculated with bacterial suspension stirred off the catheter surface.
Results:
A total number of 348 vascular catheters was examined with this new method. Positive cultures were detected in 26 (7.5 %) catheters. Accordance to the results of microbiological catheter examination with clinical condition of the patient was found in 93.1 %. False positivity occurred in 1.1 % (4) and false negativity in 5.7 % (20) of cases. On the basis of clinical symptoms 42 cases of catheter sepsis were diagnosed out of which 22 (52.4 %) positive microbiological quantitative examinations of vascular catheters were established. The most frequent pathogen was coagulase negative staphylococci.
Conclusions:
The new method, when compared with present methods, is simpler, faster and able to detect the most frequent agent of catheter infection.
More Related Videos
09:07Direct Microbial Identification using An Automated Microbial Identification System to Facilitate the EUCAST RAST Method Without Mass Spectrometry
Published on: May 24, 2024
11:28A Reference Broth Microdilution Method for Dalbavancin In Vitro Susceptibility Testing of Bacteria that Grow Aerobically
Published on: September 9, 2015