Related Experiment Video
Updated: Jul 17, 2026

A Fluorescence Fluctuation Spectroscopy Assay of Protein-Protein Interactions at Cell-Cell Contacts
Published on: December 1, 2018
The correction of reaction rates in continuous fluorometric assays of enzymes
Antônio Carlos Vassalo Alves1, Edyr Rogana, Célia de Fátima Barbosa
1Department of Physiology and Biophysics, Institute of Biological Sciences (UFMG), Avenida Pres. Antônio Carlos 6627, CEP 31270-901-Campus Pampulha, Belo Horizonte, MG Brazil.
Abstract:
The kinetic data obtained from the action of a cathepsin D-like enzyme from Biomphalaria glabrata hepatopancreas (digestive gland) on MOCAc-Gly-Lys-Pro-Ile-Leu-Phe-Phe-Arg-Leu-Lys(DNp)-D-Arg-NH(2), was studied as a data prototype, generated by means of a fluorogenic substrate. An initial fluorescence, due to incomplete energy transfer, of about 8% of the values attained after complete substrate hydrolysis; a non-linear standard curve even at microM concentrations and an exponential decay of the steady state fluorescence of reaction product of the order of 10(-4) x s(-1) were the main analytical problems encountered. The standard curves for fluorescence of the substrate reaction product after 48 h of hydrolysis, and the reference compound MOCAc-Pro-Leu-Gly-NH(2), were fitted by polynomial approximation and the point derivates used as calibration factors. Time dependence of the calibration factor for the reaction product was -2.96 x 10(-4) a.u microM(-1) x s(-1) that is, in the same order of observed enzymic reaction rates. A mathematical treatment was devised for obtaining rates corrected for errors derived from the three analytical problems indicated. The method is of general application in continuous fluorometric assays, irrespective of the particular enzyme used, but of special value for substrates that present significant initial fluorescence. The reaction rates were 11% higher; as calculated by means of the calibration factor [substrate]/(final-initial fluorescence intensities), which is the prevalent procedure in the literature; leading to underestimation of K(m) and overestimation of V(max).
More Related Videos
Related Concept Videos
Fast Reactions
Measuring Reaction Rates
Introduction to Enzyme Kinetics
The experimenter can then plot the initial reaction rate or velocity (Vo) of a given trial against the substrate concentration ([S]) to obtain a graph of the reaction properties. For many enzymatic reactions involving a...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Reaction Rate
The mathematical representation of the change in the concentration of reactants and products, over time, is the rate...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...

