Related Experiment Video
Updated: Jul 17, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Fouling mechanisms in a laboratory-scale UV disinfection system
1McGill University, Montreal, Quebec, Canada.
Abstract:
The fouling of quartz sleeves surrounding UV disinfection lamps is a perennial problem affecting both drinking water and wastewater applications. The mechanisms of fouling are not fully understood, but factors promoting fouling are believed to include heat, high hardness and/or high iron concentrations, and hydrodynamic forces. The role of UV radiation itself is unclear. The goal of this paper is to attempt to isolate the fouling mechanisms and to provide key information about those induced by UV radiation, using a unique laboratory-scale continuous-flow UV reactor. Its design allowed for irradiated and nonirradiated zones and control of both temperature and UV intensity at the fouling surface. Synthetic wastewater samples were tested with two levels of calcium, iron, phosphorus, and biochemical oxygen demand (as beef broth), and constant levels of magnesium and nitrogen to assess the effects of the four key variables. Average UV fluence before fouling exceeded 35 mJ/cm2, based on collimated beam tests. Foulant accumulation was monitored by UV intensity measurements and by mass and composition of foulant collected after an average of 56 hours of continuous operation. Tests showed that relative UV intensity dropped by as much as 100% when iron was present. Detailed results were assessed and yielded support for the following three UV-induced fouling mechanisms: (a) precipitation of ferric hydroxide [Fe(OH)3], (b) release of calcium from calcium-organics complexes followed by precipitation of iron-organics complexes, and (c) calcium carbonate precipitation. Other fouling mechanisms, such as sedimentation of preformed particles and sorption of calcium onto preformed colloids of Fe(OH)3, occurred outside the zone of UV radiation. Hence, these could be confused with concurrent UV-induced mechanisms in full-scale reactors. Iron and/or calcium undoubtedly created the most favorable conditions for fouling to occur; in the absence of both, fouling would be unlikely. The rates of fouling were enhanced when organics were also present; however, when phosphorus was present, fouling in the UV section was reduced. Indeed, UV may be viewed as inhibiting the fouling caused by phosphate complexes.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Scale-Up Processes
Bioreactor Controls-II
Biological Treatment of Effluent and Waste Water