Through-the-Wall Blood Sampling Method to Minimize Sleep Disruption in Clinical Settings
Published on: June 13, 2025
A new technique for detecting sleep apnea-related "midnight" surge of blood pressure
Osamu Shirasaki1, Shingo Yamashita, Shin-ichi Kawara
1Business Development Center, Omron Healthcare, Co., Ltd., Kyoto, Japan.
Abstract:
Patients with obstructive sleep apnea syndrome (OSAS) have been reported to be at greater risk for cardiovascular events, and midnight surge of blood pressure (BP) may be a mechanism of sleep apnea-related cardiovascular risk. However, there has been no accurate noninvasive technique to detect intermittent BP surge at the time of each sleep apnea episode. We therefore developed an experimental system to detect apnea-related short-term BP surge based on BP measurement triggered by peripheral (finger-tip) oxygen desaturation (a desaturation-triggered BP monitoring system). In 16 patients with OSAS, this new system successfully detected BP surges at the time of the sleep apnea, and the BP values were found to be significantly higher than those detected using a conventional fixed interval BP monitoring system (systolic BP [SBP] difference: 13 +/- 5.8 mmHg, p = 0.039; diastolic BP [DBP] difference: 10 +/- 6.8 mmHg, p = 0.032). The maximum SBP time rate (velocity of BP surge) showed a strong positive correlation with the apnea-hypopnea index (r = 0.855, p < 0.0001). In conclusion, we developed a noninvasive oxygen desaturation-triggered BP monitoring system that can successfully detect sleep apnea-related BP surge. The midnight BP surge detected by this new method was significantly associated with the severity of OSAS.
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: