Related Experiment Video
Updated: Jul 16, 2026

A Tactile Automated Passive-Finger Stimulator (TAPS)
Published on: June 3, 2009
A Bayesian analysis of the true sensitivity of a temporal artery biopsy
Ryan D Niederkohr1, Leonard A Levin
1Division of Nuclear Medicine, Stanford University Hospital and Clinics, Stanford, California, USA.
Purpose:
The temporal artery biopsy (TAB) has long been the standard for diagnosing temporal arteritis (TA), but in practice this test is less than 100% sensitive; false-negative biopsy results are known to occur. The true sensitivity of a single TAB cannot be directly observed, because there is no true gold standard for comparison. The authors propose a mathematical method for calculating the true sensitivity of the TAB, using data from published bilateral TAB RESULTS:
Methods:
Based on Bayesian methodology, this statistical technique can be used to calculate the true sensitivity of a single TAB with data from studies reporting the results of bilateral simultaneous TABs. This technique also allows for calculation of the true prevalence of TA in a study population. Bootstrap techniques are used to provide confidence intervals. This technique is applied to data derived from four studies in the literature. results. With this methodology, the sensitivity of a single TAB is calculated to be 87.1% (95% confidence interval, 81.8%-91.7%).
Conclusions:
Knowledge of the true sensitivity of any imperfect test is necessary for an accurate decision analysis, because it can affect the optimal diagnostic-therapeutic pathway. Although few studies report results of bilateral simultaneous TABs, such data are important because they permit the calculation of the true TAB sensitivity. The authors believe that this mathematical method is superior to observational methods (e.g., clinical criteria) for estimating the true sensitivity of a TAB.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...