Simultaneous concentration and separation of coumarins using a molecular micelle in micellar affinity gradient
Mary W Kamande1, David Ross, Laurie E Locascio
1Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, USA.
Abstract:
We report the use of a molecular micelle for the simultaneous separation and concentration of neutral and hydrophobic analytes using micellar affinity gradient focusing (MAGF). The technique, MAGF, combines the favorable features of micellar electrokinetic chromatography and temperature gradient focusing. The focusing of neutral coumarin analytes was accomplished by the use the molecular micelle, poly(sodium undecenyl sulfate) (poly-SUS). Concentration enhancements of 10-25-fold/min were achieved for focusing of the coumarin dyes. The effect of varying the temperature gradient on the resolution of two of the coumarin dyes was also investigated, demonstrating that improved resolution could be achieved by reducing the steepness of the temperature gradient. In addition, with scanning-mode MAGF (in which the peaks are sequentially scanned past a fixed detection point by varying the buffer counterflow velocity), the use of poly-SUS was shown to produce repeatable and quantitative analyte peaks, making quantitative separations possible with the MAGF technique. Finally, it was shown that peak areas could be increased in scanning MAGF by reducing the scan rate so that the sensitivity of the method can be adjusted as needed.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Micelles
Affinity Chromatography
Ion-Exchange Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
