Related Experiment Video
Updated: Jul 17, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Non-invasive radial pulse wave assessment for the evaluation of left ventricular systolic performance in heart
Jean-Michel Tartiere1, Damien Logeart, Florence Beauvais
1Department of Physiology, Lariboisière Hospital, Assistance Publique, Paris, France. jean-michel.tartiere@lrb.ap-hop-paris.fr
Introduction:
Left ventricular (LV) developed pressure (dP/dt) is a classical index of myocardial contractility related to prognosis during heart failure. We sought to assess the reproducibility and feasibility of use of the maximal first derivative of the radial pulse, Rad dP/dt, as a peripheral criterion of ventricular contractility in patients with heart failure.
Methods:
We assessed 50 consecutive, patients with heart failure using aplanation tonometry to record the radial pulse wave and calculate Rad dP/dt. Echocardiography, Doppler flow and tissue Doppler imaging were used to record classical parameters of LV function: LV ejection fraction (LVEF), Tei index, dP/dt on mitral regurgitation (MR dP/dt) and peak systolic velocity (S'). Total systemic vascular resistance (TSVR) was calculated by use of the Doppler calculated cardiac output. Preload was assessed by the E/Ea ratio. Feasibility was tested in an ongoing prospective mortality study (n=310).
Results:
The Bland and Altman representation of repeated measurements of the Rad dP/dt showed good agreement. Feasibility was greater than 99% for a successful assessment on the right arm during the first attempt. The Rad dP/dt correlated with the LVEF, S' or Tei index as usual parameters of impaired contractility but not preload (E/Ea) or afterload (TSVR) parameters. MR dP/dt and Rad dP/dt were closely related (r=0.75, p<0.001). The ability of the arterial dP/dt to characterize LVEF was not modified by adjustment for arterial viscoelastic properties.
Conclusion:
The maximal dP/dt of the radial pulse appears to be a valuable and reproducible peripheral criterion of LV systolic performance.
More Related Videos
08:57Pulsed Wave Doppler Assessment of Diastolic Dysfunction in the ZSF-1 Rat Model of Pulmonary Hypertension Due to Left Heart Disease
Published on: May 22, 2026
07:38Comprehensive Echocardiographic Assessment of Right Ventricle Function in a Rat Model of Pulmonary Arterial Hypertension
Published on: January 20, 2023
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...