Related Experiment Video
Updated: Jul 17, 2026

Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Characterization of new nitrosamines in drinking water using liquid chromatography tandem mass spectrometry
Yuan-Yuan Zhao1, Jessica Boyd, Steve E Hrudey
1Environmental Health Sciences, School of Public Health and Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, 10-102 Clinical Sciences Building, Edmonton, Alberta, Canada T6G 2G3.
Abstract:
N-Nitrosodimethylamine (NDMA), a member of a group of probable human carcinogens, has been detected as a disinfection byproduct (DBP) in drinking water supplies in Canada and the United States. To comprehensively investigate the occurrence of possible nitrosamines in drinking water supplies, a liquid chromatography-tandem mass spectrometry technique was developed to detect both thermally stable and unstable nitrosamines. This technique consisted of solid-phase extraction (SPE), liquid chromatography (LC) separation, and tandem quadrupole linear ion trap mass spectrometry (MS/MS) detection. It enabled the determination of sub-ng/L levels of nine nitrosamines. Isotope-labeled N-nitrosodimethylamine-d6 (NDMA-d6) was used as the surrogate standard for determining recovery, and N-nitrosodi-n-propylamine-dl4 (NDPA-dl4) was used as the internal standard for quantification. The method detection limits were estimated to be 0.1-10.6 ng/L, and the average recoveries were 41-111% for the nine nitrosamines; of these, NDMA, N-nitrosopyrrolidine (NPyr), N-nitrosopiperidine (NPip), and N-nitrosodiphenylamine (NDPhA) were identified and quantified in drinking water samples collected from four locations within the same distribution system. In general, the concentrations of these four nitrosamines in this distribution system increased with increasing distance from the water treatment plant, indicating that the amount of formation was greater than the amount of decomposition within this time frame. The identification of NPip and NDPhA in drinking water systems and the distribution profiles of these nitrosamines have not been reported previously. These nitrosamines are toxic, and their presence as DBPs in drinking water may have toxicological relevance.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
07:38A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
2° Amines to N-Nitrosamines: Reaction with NaNO2
Mass Spectrometry of Amines