Measurement of dissolved H2, O2, and CO2 in groundwater using passive samplers for gas chromatographic analyses
1Environmental Sciences Division, Oak Ridge National Laboratory, P.O. Box 2006, Oak Ridge, Tennessee 37831, USA. spaldingbp@ornl.gov
Abstract:
A simple in-situ passive dissolved gas groundwater sampler, comprised of a short length of silicone tubing attached to a gastight or other syringe, was adapted and tested for in-situ collection of equilibrium gas samples. Sampler retrieval after several days of immersion in groundwater allowed the direct injection of the sample onto a gas chromatograph (GC), simplifying field collection and sample handling over the commonly used "bubble stripping" method for H2 analyses. A GC was modified by sequencing a thermal conductivity (TC) detector followed by a reductive gas (RG) detector so that linear calibration of H2 over the range 0.2-200,000 ppmv was attained using a 0.5-mL gas sample; inclusion of the TC detector allowed the simultaneous quantification of other fixed gases (O2, CO2, He, and Ne) to which the RG detector was not responsive. Uptake kinetics for H2 and He indicated that the passive sampler reached equilibrium within 12 h of immersion in water. Field testing of these passive samplers revealed unusually large equilibrium gas-phase H2 concentrations in groundwater, ranging from 0.1 to 13.9%, by volume, in 11 monitoring wells surrounding four former radiological wastewater disposal ponds at the Y-12 plant in Oak Ridge, Tennessee.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Volatilization
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...