Characterizing dissolved and particulate phosphorus in water with 31P nuclear magnetic resonance spectroscopy

Barbara J Cade-Menun1, John A Navaratnam, Mark R Walbridge

  • 1Department of Geological and Environmental Sciences, Stanford University, Stanford, California 94305-2115, and Department of Biology, West Virginia University, Morgantown, West Virginia 26506-6057, USA. bjcm@pangea.stanford.edu

Related Concept Videos

Other Nuclides: 31P, 19F, 15N NMR01:16

Other Nuclides: 31P, 19F, 15N NMR

Many organic, inorganic, and biological molecules contain spin-half nuclei such as nitrogen-15, fluorine-19, and phosphorus-31. As a result, NMR studies of these nuclei have found extensive applications in chemical and biological research.
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a high...
The Phosphorus Cycle01:21

The Phosphorus Cycle

Unlike carbon, water, and nitrogen, phosphorus is not present in the atmosphere as a gas. Instead, most phosphorus in the ecosystem exists as compounds, such as phosphate ions (PO43-), found in soil, water, sediment and rocks. Phosphorus is often a limiting nutrient (i.e., in short supply). Consequently, phosphorus is added to most agricultural fertilizers, which can cause environmental problems related to runoff in aquatic ecosystems.
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...