Catheter-based infrared light scanner as a tool to assess conduit quality in coronary artery bypass surgery
Nicholas Burris1, Kimberly Schwartz, Cha-Min Tang
1Department of Cardiac Surgery, University of Maryland, School of Medicine, Baltimore, Md 21201, USA.
Objectives:
Endothelial disruption within saphenous vein and radial artery grafts increases thrombosis risk. However, no clinically applicable method for imaging the intima currently exists. We used a novel infrared imaging technology, optical coherence tomography (OCT; LightLab Imaging, Inc, Westford, Mass), to visualize the intima within harvested conduits.
Methods:
Conduits were procured endoscopically (37 saphenous vein grafts and 8 radial artery grafts) or with the open technique (9 radial artery grafts) from 50 patients. Surplus segments were analyzed by means of OCT for evidence of preexisting pathology or traumatic injury. Focal plaques in radial artery grafts and the intimal hyperplasia area in saphenous vein grafts were quantified as having an intimal/medial thickness ratio of greater than 0.5. Biopsy specimens were obtained for histologic confirmation and to analyze matrix metalloproteinase 2 levels (saphenous vein grafts) and prostacyclin/nitric oxide metabolites (radial artery grafts). Interobserver kappa coefficients and a Bland-Altman analysis were used to determine the reproducibility and accuracy of OCT interpretations.
Results:
Radial artery imaging revealed plaque in 76%. Endoscopically harvested vessels showed intraluminal clot (38%) and intimal tears ranging from severe (6%) to mild (88%). In saphenous vein grafts intimal thickening was detected in 86% and intraluminal clotting in 68%. The intimal/medial thickness ratio determined by means of OCT correlated directly with matrix metalloproteinase 2 levels (R = 0.6804) in saphenous vein grafts and inversely with metabolites of prostacyclin (R = -0.55) and nitric oxide (R = -0.58) in radial artery grafts. OCT imaging was reproducible (interobserver kappa coefficients of >0.81 for the characterization of plaque types) and showed a strong correlation with histology (R = 0.8, P < .001).
Conclusions:
OCT imaging provides an accurate, real-time, and reproducible means for assessing saphenous vein graft and radial artery graft bypass conduits. As a quality assurance tool, this technology might afford a more objective basis for conduit selection.
More Related Videos
08:51Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Acute Coronary Syndrome III: Diagnostic Studies