The Frequency Domain Thermoreflectance Technique for Thermal Property Measurements
Published on: December 5, 2025
Temporal resolution of the skin impedance measurement in frequency-domain method
Takenori Fukumoto1, Gwang-Moon Eom, Shigeo Ohba
1Healthcare Business Company, Matsushita Electric (Panasonic), Yokohama, 224-8539 Japan. fukumoto.takenori@jp.panasonic.com
Abstract:
The temporal-resolution of the frequency-domain method for the identification of the impedance locus depends on the basis frequency used in the current waveform construction, i.e., the higher basis frequency provides the better temporal resolution. The impedance locus can be characterized by the impedance parameters Z0, beta, and taum. The frequency distribution of limited number of data in the impedance locus would affect the accuracy of the estimated impedance parameters. Therefore, we investigated the relationship between the estimation accuracy of the impedance parameters and the frequency coverage of the impedance locus in relatively low to high impedance conditions (dc impedance Z0= 51 k ohms - 45 M ohms). As the basis frequency, 100 Hz was enough for the usual impedance with Z0 less than 203 k ohms. On the other hand, 10 Hz and 1 Hz were required for the medium-level (Z0 = 517 k ohms), and high-level (Z0 = 45 M ohms) impedance, respectively. The required basis frequency, accordingly the temporal resolution, depended much on the central relaxation time taum which affects the frequency distribution on the impedance locus. The results of this study are expected to serve as the reference of the frequency selection in the frequency-domain analysis of the skin impedance.
Related Concept Videos
Bode Plots Construction
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Discrete Fourier Transform