High flow nasal cannula versus nasal CPAP for neonatal respiratory disease: a retrospective study
M T Shoemaker1, M R Pierce, B A Yoder
1Wilford Hall USAF Medical Center, Lackland AFB, TX 78236, USA. michael.shoemaker@lackland.af.mil
Objective:
Our objective is to assess the frequency of usage, safety and clinical utility of humidified high flow nasal cannula (HHFNC) in two tertiary care hospitals and compare outcomes to a historical control group of premature infants who received nasal continuous positive airway pressure (NCPAP).
Study Design:
The first part of the study describes the increased HHFNC usage in two tertiary neonatal intensive care units. The second part compares outcomes of infants, born at less than 30 weeks gestation, who received either NCPAP or HHFNC as an early respiratory support mode.
Results:
HHFNC usage increased (64%) after its introduction in infants of all gestational ages whereas the usage of NCPAP decreased from 19 to 4%. Ninety-five percent of infants born at less than 30 weeks gestation received HHFNC at some point during their hospital stay whereas only 12% received NCPAP. There were no differences in death or bronchopulmonary dysplasia (BPD), but ventilator-days per patient were decreased (19.4 to 9.9) following introduction of HHFNC. Comparing the cohort of infants who received either NCPAP or HHFNC as an early mode of respiratory support, there were no differences in deaths, ventilator-days, BPD, blood infections or other outcomes. More infants were intubated for failing early NCPAP compared to early HHFNC (40 to 18%).
Conclusions:
HHFNC was well-tolerated by premature infants. Compared to infants managed with NCPAP, there were no apparent differences in adverse outcomes following the introduction of HHFNC. Additional research is needed to better define the utility and safety of HHFNC compared to NCPAP.
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Suctioning the Nasopharyngeal Airway
Equipment Required