Multiresidue analysis of seven anticoagulant rodenticides by high-performance liquid chromatography/electrospray/mass
LeEtta J Marek1, William C Koskinen
1Minnesota Department of Agriculture, 601 Robert Street North, St. Paul, MN 55155, USA. LeEtta.Marek@state.mn.us
Abstract:
Mice and rat populations are commonly controlled by two classes of rodenticide anticoagulants, coumarins and indandiones. However, poisoning of nontarget animals also often occurs. For cases such as these, a rapid, multiresidue method, which provides positive confirmation for both classes of anticoagulant rodenticides, is needed by diagnostic laboratories. A method was developed for the determination of seven anticoagulant rodenticides, coumafuryl, pindone, warfarin, diphacinone, chlorophacinone, bromadiolone, and brodifacoum, in diverse matrices, animal feed, cooked beef, and fruit-flavored beverages using high-performance liquid chromatography/electrospray/mass spectrometry. Detection was by MS/MS with electrospray ionization in negative mode. Confirmation was by retention time, m/z of molecular ion, and two parent-daughter transitions. Recoveries from selected the matrices ranged from 61 to 117%. Limits of quantitation were as low as 1.5-4.5 ng g-1. The developed method was rapid and provided the simultaneous confirmation and quantification of the seven anticoagulant rodenticides.