Related Experiment Video
Updated: Jul 17, 2026

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
Published on: February 4, 2011
Finite element modelling of a 3 dimensional dielectrophoretic flow separator device for optimal bioprocessing
1Centre for Biomed. Eng., Surrey Univ., Guildford, UK.
Abstract:
Planar 2-dimensional dielectrophoresis electrode geometries are limited in only being capable of handling fluid volumes ranging from picolitres to hundreds of microliters per hour. A 3-dimensional electrode system has been developed capable of handling significantly larger volumes of fluid. Using finite element modeling the electric field distribution within various bore sizes was realized. From these simulations it is possible to optimize bioprocessing factors influencing the performance of a dielectrophoretic separator. Process calculations have shown that flow-rates of 25ml hr/sup -1/ or more can be attained for the separation of heterogeneous populations of bio-particles based on their dielectric properties.