Using a forehead reflectance pulse oximeter to detect changes in sympathetic tone.
Suzanne M Wendelken1, Susan P McGrath, Metin Akay
1Thayer Sch. of Eng., Dartmouth Coll., Hanover, NH, USA.
Summary
Forehead pulse oximeters can detect changes in sympathetic tone, aiding in field triage. This automated remote triage system (ARTEMIS) uses PPG signals to assess patient status in emergencies.
Area of Science:
- Biomedical Engineering
- Physiological Monitoring
- Emergency Medicine
Background:
- Field triage in combat and disaster zones is challenging and risky for responders.
- Massive blood loss or shock causes arterial pressure changes, activating the sympathetic system.
- Current methods may not adequately assess physiological status in extreme environments.
Purpose of the Study:
- To evaluate a forehead reflectance pulse oximeter as a sensor for detecting sympathetic tone changes.
- To assess the viability of the automated remote triage system (ARTEMIS) for battlefield and disaster use.
- To explore signal processing techniques for analyzing photoplethysmogram (PPG) data.
Main Methods:
- Collected continuous PPG waveforms using a forehead reflectance pulse oximeter during a supine-standing experiment.
- Processed raw PPG signals and derived pulse statistics (height, beat-to-beat interval) using spectral analysis (FFT, AR) in Matlab.
- Analyzed the low frequency power/high frequency power ratio to detect changes in sympathetic tone.
Main Results:
- Preliminary results indicate that relative ratio analysis of PPG signals is effective in detecting sympathetic tone changes.
- Both raw PPG data and derived pulse statistics showed changes correlating with positional changes.
- The forehead reflectance pulse oximeter demonstrated potential as a sensor for sympathetic tone monitoring.
Conclusions:
- A forehead reflectance pulse oximeter is a viable sensor for detecting sympathetic tone fluctuations.
- Relative ratio analysis of PPG signals offers a useful technique for assessing physiological changes in emergency settings.
- The ARTEMIS system shows promise for improving field triage and emergency management.
More Related Videos
Related Concept Videos
Pulse Oximetry
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical pulse
Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation