Related Experiment Video
Updated: Jul 17, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Improving spatial signal homogeneity in MR 2D chemical shift imaging using outer volume saturation bands
Abstract:
Many endeavors of improving chemical shift imaging (CSI) techniques have been made during last two decades. Good examples of two-dimensional CSI and three-dimensional CSI can be found in the literature. However, clinical CSI using available sequences is still not satisfactory. The purpose of this study was to assess the effect of outer volume saturation bands on signal homogeneity in MR 2D chemical shift imaging. The 2D CSI scans were acquired using a point resolved spectroscopy (PRESS) CSI sequence on a phantom filled with brain metabolites. A single PRESS volume of interest was prescribed graphically. The acquisition matrix was 18x18 phase encodings over a 24-cm FOV. Identical acquisitions were obtained with and without outer-volume saturation bands. After initial acquisition was obtained, four more acquisitions were repeated for both studies with and without saturation bands. Identical five groups of voxels were compared for both studies. Standard deviations of metabolite ratios were calculated in each group for both studies. Spectra obtained without outer-volume saturation bands showed signal to noise gradient with higher concentration of signal within voxels at the center of the volume of interest. Outer volume saturation bands reduced this gradient. In general, standard deviations of metabolite ratios with saturation bands were smaller than those without saturation bands. Improved spatial homogeneity of spectra in voxels of CSI with saturation bands was obtained. Outer-volume saturation bands improve spatial signal homogeneity of chemical shift imaging.
Related Concept Videos
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse.
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
NMR Spectrometers: Resolution and Error Correction
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
2D NMR: Overview of Heteronuclear Correlation Techniques

