Monitoring the Wall Mechanics During Stent Deployment in a Vessel
Published on: May 8, 2012
Ultrasonic techniques for assessing wall vibrations in stenosed arteries
1Dept. of Electr. Eng., Washington Univ., Seattle, WA, USA.
Abstract:
Arterial stenoses are often associated with audible bruits. Quantitative analysis of the bruit spectrum has been successfully used to predict the residual lumen diameter in carotid stenoses. Arterial wall vibrations occurring due to turbulent pressure fluctuations in the post-stenotic jet are known to be the source of the bruits. We present novel signal processing techniques that enable the detailed noninvasive assessment of these vibrations in real time using color-Doppler and pulsed-wave Doppler ultrasound. A color-Doppler-based two-dimensional vibration imaging technique can be used to locate the source of the bruits relative to the underlying anatomy. Subsequently, a pulsed-wave Doppler-based technique can be used to analyze the bruit spectrum quantitatively. Experiments in ex vivo arteries indicate that these techniques can predict the location of the bruit as well as its spectral content. Case studies on human subjects with stenosed vein grafts are presented and the clinical applicability of this technique is discussed.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...