Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Enhanced fluorescence emission using a programmable, reconfigurable LED-array based light source.

Andrew Moe1, Naureen Banani, Linda Lee

  • 1Department of Electrical Engineering, University of Washington, Seattle, WA 98195, USA.

Conference Proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
|February 3, 2007
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Living with Xeroderma Pigmentosum: a qualitative study of the psychosocial challenges experienced by families of children with a rare skin disorder.

Orphanet journal of rare diseases·2026
Same author

Improving the Delivery of Brain Health Care to All. Keeping our Eye on the Main Prize in an Era of Emerging Anti-Amyloid Therapies.

Canadian geriatrics journal : CGJ·2026
Same author

Feasibility and Acceptability of a Virtual Home Assessment for Supporting People with Dementia to Live at Home.

Home healthcare now·2026
Same author

Personalized Predictive Model to Predict Subtask Success of Medication Adherence Technologies for Older Adults With Diverse Capabilities: Development and Internal Validation Study.

JMIR aging·2026
Same author

Ka Muri, Ka Mua Indigenous Nursing: How the Past Can Inform Moving Into the Future.

Journal of advanced nursing·2026
Same author

Transcatheter Tricuspid Valve Intervention Risk Scores: Assessment in an International Multicenter Cohort.

JACC. Cardiovascular interventions·2026
Same journal

Highly Articulated Robotic Probe for Minimally Invasive Surgery.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2010
Same journal

Combined peripheral and cortical neural stimulation in motor neurorehabilitation.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

Embedded assessment algorithms within home-based cognitive computer game exercises for elders.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

Digital signal processing of the wideband external pulse recorded during cuff deflation: a new way to measure blood pressure.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

Immune cells detection of the in vivo rejecting heart in USPIO-enhanced magnetic resonance imaging.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2008
Same journal

wHospital: a web-based application with digital signature for drugs dispensing management.

Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference·2007
See all related articles

An optimized LED array offers millions of spectral configurations for fluorescence analysis. This flexible system enhances signal-to-noise ratios, outperforming conventional lamps for improved analytical sensitivity.

Area of Science:

  • Optical Engineering
  • Analytical Chemistry
  • Biophotonics

Background:

  • Traditional excitation sources in fluorescence analysis, such as Xenon lamps, have limitations in spectral tunability.
  • Optimizing excitation spectra is crucial for maximizing signal output and improving the signal-to-noise ratio in fluorescence measurements.

Purpose of the Study:

  • To develop and evaluate a versatile LED array system for optimizing excitation signals in fluorescence analysis.
  • To demonstrate the enhanced flexibility and performance of a tunable LED array compared to conventional excitation sources.

Main Methods:

  • An array of up to 5 LEDs was configured with varying types and drive currents to tune the aggregate spectrum.
  • The performance of the optimized LED array was experimentally compared against a Xenon lamp using AM1 bacteria and Rhodamine G.

Related Experiment Videos

  • Signal-to-noise ratio and emission output were key metrics for evaluating system performance.
  • Main Results:

    • The LED array demonstrated significant flexibility, offering up to 3.2 million aggregate spectral possibilities.
    • Experiments showed comparable emission output between an overdriven LED array and a conventional Xenon lamp.
    • A two-fold improvement in signal-to-noise ratio was achieved with the optimized LED array for Rhodamine G detection.

    Conclusions:

    • A tunable LED array provides a highly flexible and effective alternative to conventional excitation sources for fluorescence analysis.
    • Optimizing the excitation spectrum using the LED array significantly enhances analytical sensitivity and signal quality.