Related Experiment Video
Updated: Jul 17, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Use of 3-dimensional color Doppler echocardiography to measure stroke volume in human beings: comparison with
Joseph A Lodato1, Lynn Weinert, Rolf Baumann
1Noninvasive Cardiac Imaging Laboratory, Section of Cardiology, Department of Internal Medicine, University of Chicago Medical Center, Chicago, Illinois 60637, USA.
Background:
The availability of accurate noninvasive measurements of cardiac output (CO) would be useful in assessing disease severity and the effects of therapeutic interventions in many different clinical settings. Current noninvasive methods are limited by their dependence on geometric assumptions. We tested the feasibility of a new technique for CO measurements based on 3-dimensional color Doppler echocardiographic (3D-CD) imaging.
Objective:
We sought to compare the accuracy of CO determination in human beings as measured by 3D-CD and conventional 2-dimensional echocardiography (2DE) using thermodilution as the gold standard for comparison.
Methods:
Simultaneous 3D-CD, 2DE, and thermodilution data were acquired in 47 patients postcardiac transplantation with good acoustic windows who required routine hemodynamic evaluation with a pulmonary artery catheter. Data were stored on compact disc and analyzed offline using custom software. Echocardiographic data were compared against thermodilution using linear regression and Bland-Altman analysis.
Results:
Correlation coefficients for 3D-CD and 2DE of the left ventricular outflow tract were r = 0.94 and r = 0.78, respectively. Correlation coefficients for 3D-CD and 2DE of the mitral valve were r = 0.93 and r = 0.75, respectively. Compared with 2DE, 3D-CD demonstrated a smaller bias and narrower limits of agreement in the left ventricular outflow tract (-1.84 +/- 16.8 vs -8.6 +/- 36.2 mL) and mitral valve inflow (-0.2 +/- 15.6 vs 10.0 +/- 26 mL).
Conclusion:
The 3D-CD determination of CO is feasible and accurate. Compared with previous noninvasive modalities, 3D-CD has the advantages of independence of geometric assumptions and ease of image acquisition and analysis.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
