Related Experiment Video
Updated: Jul 17, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Increased impedance to inspiration ameliorates hemodynamic changes associated with movement to upright posture in
Daniel P Melby1, Fei Lu, Scott Sakaguchi
1Cardiac Arrhythmia Center and Syncope Center, Cardiovascular Division, Department of Medicine, University of Minnesota, Minneapolis, Minnesota 55455, USA.
Background:
Movement to upright posture may result in marked drop of blood pressure with susceptibility to injury from syncope and falls in patients with orthostatic hypotension.
Objective:
The purpose of this study was to determine if increasing negative intrathoracic pressure by using an inspiratory impedance threshold device before change of posture diminishes blood pressure fall by enhancing venous return.
Methods:
Eighteen healthy subjects and 22 orthostatic hypotension patients were randomized to either an active (impedance 7 cmH2O) or sham (no inspiratory impedance) impedance threshold device. Arterial blood pressure, heart rate, and estimated stroke volume and total peripheral resistance were recorded in the supine and upright postures using a noninvasive finger arterial blood pressure monitor. After a rest period, the alternate impedance threshold device (sham or active) was tested in each individual.
Results:
Compared with the sham impedance threshold device test, the active impedance threshold device resulted in significant reduction in the magnitude of upright posture-induced fall in blood pressure and a greater increase of total peripheral resistance after standing in both healthy subjects and orthostatic hypotension patients. Stroke volume was not measurably altered. Among all subjects who exhibited a postural blood pressure drop >10 mmHg on the day of study, active impedance threshold device treatment consistently blunted blood pressure fall during the initial 100 seconds after standing (<0.04). Induced orthostatic symptoms were less severe with the active impedance threshold device both at onset of upright posture and during 30 seconds of standing.
Conclusion:
Enhancing impedance to inspiration may prove useful as adjunctive therapy for diminishing symptoms associated with movement to upright posture in individuals with orthostatic hypotension.
Related Concept Videos
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart beats)...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.