Identification of Vascular Dynamics and Estimation of the Cardiac Output Waveform from Wearable PPG Sensors
D McCombie1, H Asada, A Reisner
1Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA.
Abstract:
A method for estimating cardiovascular dynamics and cardiac output waveforms using signals derived from two PPG sensors is presented. The method employs a novel signal-processing algorithm known as Laguerre Model Blind System Identification to identify the vascular dynamics associated with the measured PPG signals. A unique deconvolution method is then used with the identified Laguerre models to estimate the cardiac output waveform. Initial results implementing the method on data derived from a human subject is presented. Results show good agreement between the morphology of the estimated waveform and the typical morphology of the human cardiac output waveform.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation