Related Experiment Video
Updated: Jul 17, 2026

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
A Bedside System for Combined RNA and PAC in Heart Failure.
A new bedside system combines radionuclide angiography and pulmonary artery catheterization for accurate right ventricular (RV) and left ventricular (LV) function assessment. This novel method generates RV pressure-volume loops, crucial for heart failure evaluation.
Area of Science:
- Cardiology
- Medical Imaging
- Physiology
Background:
- Assessing right ventricular (RV) function is challenging due to its complex geometry.
- Existing methods for RV function assessment often lack accuracy and are geometrically dependent.
Purpose of the Study:
- To develop and validate a novel bedside system for simultaneous, accurate assessment of RV and LV systolic function.
- To enable precise calculation of ventricular volumes and generation of RV pressure-volume loops.
Main Methods:
- Integration of a multiwire gamma camera (MWGC) with pulmonary artery catheterization (PAC).
- Simultaneous acquisition of first-pass radionuclide angiography (RNA) images, pulmonary artery pressure data, and thermodilution data.
- Non-geometric calculation of RV and LV ejection fractions and volumes.
Main Results:
- The system provides highly accurate quantitative measurements of RV and LV ejection fractions.
- Accurate calculation of ventricular volumes by dividing stroke volume by ejection fraction.
- Successful generation of RV pressure-volume loops, critical for heart failure (HF) patient evaluation.
Conclusions:
- The hybrid RNA-PAC system offers a novel, accurate, and reproducible method for assessing RV function.
- This technique surpasses current modalities in accuracy for ventricular volume measurement.
- The system is valuable for evaluating heart failure patients by providing RV pressure-volume loops.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
07:49A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
Published on: July 21, 2023
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Heart Failure IV: Classification and Diagnostic Evaluation
Heart Failure II: Pathophysiology
Heart Failure V: Medical Management
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure I: Introduction