Limitations of ICA for Artefact Removal
Djuwari Djuwari1, Dinesh Kant Kumar, Marimuthu Palaniswami
1PhD student at Faculty of Engineering, School of Electrical and Computing Engineering, RMIT University, Melbourne, Vic., Australia, 3000 s3001068@student.rmit.edu.au.
Abstract:
This paper reports analysis of the limitations of using Independent Component Analysis (ICA) for biosignal analysis especially artefact removal. The possible difficulty is that there are limited number of electrodes (recordings) making it an overcomplete problem (non-square ICA). The other difficulty is the distribution of biosignal being close to Gaussian. These two properties of the signals may make these outside the standard ICA application. This paper reports that ICA is able to successfully separate the biosignals if the number of recordings are not less than the number of sources. If that is not the case, ICA separates artefact component only when the corresponding artefact is predominant. The experiments demonstrate that the results are not reliable and hence the authors recommend that caution should be exercised before using ICA for such applications.
More Related Videos
06:39Electroencephalographic, Heart Rate, and Galvanic Skin Response Assessment for an Advertising Perception Study: Application to Antismoking Public Service Announcements
Published on: August 28, 2017
09:01A Method for Investigating Age-related Differences in the Functional Connectivity of Cognitive Control Networks Associated with Dimensional Change Card Sort Performance
Published on: May 7, 2014
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...