Automated leakage current measurement for medical equipment safety
1Institute of Biomedical Engineering, Chinese Academy Of Medical Sciences & Peking Union Medical College; Department of Orthopaedics and Traumatology, The University of Hong Kong.
Abstract:
Electrical safety is always an important item of medical equipment in hospital. With the development of clinical engineering, the electric safety testing has become a routine procedure for the unit of clinical engineering in hospital. Among the parameters of safety standard of medical equipment, the leakage currents are more important than others. This study is aimed in the measurement of different leakage currents. An intelligent and digital tester was applied to test the safety quality of medical instrument automatically. This tester was based on a chip-computer (INTER 8031). This tester was designed to be able to set up as normal status or single failure status for automatic test by electric relays. All the results, free from manual errors, are displayed by means of a LCD unit and printed by a micro-printer. The output of high accuracy is also an advantage of this instrument, which is based on a precise signal detection electrical circuit and adaptive filter. This tester can be easily used for the clinic unit follow the standard of China GB9706 as well as IEC standard 601 and UL2601.
Related Concept Videos
Controlled-Current Coulometry: Overview
Ammeter
When an ammeter is used to measure the...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Amperometry: Overview
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...