A Correction Method of Medical Thermography's Distortion
Zhenglong Chen1, Guotai Jiang, Fuhui Zheng
1School of Bio-Science and Technology, Tongji University, Shanghai, China.
Abstract:
A problem of temperature distortion of medical thermography of the limb ending which results from different infrared radiant intensity of points detected by infrared detector was discussed. Further the difference of the radiant intensity is caused by that of projecting angles of points. Subsequently through related theory and experiments this paper found that the temperature shown by thermography bears a Gauss attenuation relation to actual surface temperature of an object. A Gaussian Matching Arithmetic was put forward to correct this kind of temperature distion. Finally, by using this Arithmetic a temperature distortion of thermography of a finger was corrected and the results were exciting.
Related Concept Videos
Distance Corrections
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...