Simultaneous determination of diallyl trisulfide and diallyl disulfide in rat blood by gas chromatography with electron-capture detection
1Department of Pharmacy, General Hospital of Shenyang Military Region, Shenyang, China.
Abstract:
A simple, rapid and sensitive method has been developed and validated for the simultaneous quantification of diallyl trisulfide (DATS) and diallyl disulfide (DADS) in rat blood by gas chromatography with electron-capture detection. The analytes were prevented from degradation by addition of acetonitrile and extraction with hexane before gas chromatographic separation. Two calibration curves for DATS were linear over the range of 10-500 ng/mL and 0.2-20 microg/mL, with typical r values of 0.9989 and 0.9993, respectively. Similarly, two calibration curves for DADS were linear in the concentration range of 50-5000 ng/mL and 1-30 microg/mL, with typical r values of 0.9989 and 0.9983, respectively. The limit of detection was less than 10 ng/mL for DATS and 50 ng/mL for DADS, and the assay was highly reproducible, considering the intra-, inter-day relative standard deviations (R.S.D.) below 12%. The developed procedure was successfully applied for the evaluation of the pharmacokinetics of garlic oil following iv administration at a single dose (10 mg) of garlic oil in rats. The results show that the developed method is suitable for pharmacokinetic and therapeutic purposes of DATS and DADS.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
10:11Microdialysis of Ethanol During Operant Ethanol Self-administration and Ethanol Determination by Gas Chromatography
Published on: September 5, 2012
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...