Related Experiment Video
Updated: Jul 17, 2026

Homogeneous Time-resolved Förster Resonance Energy Transfer-based Assay for Detection of Insulin Secretion
Published on: May 10, 2018
Stability of insulin under iontophoretic conditions
R Panchagnula1, P Bindra, N Kumar
1Department of Pharmaceutics, National Institute of Pharmaceutical, Education and Research (NIPER), Mohali, Punjab, India. panchagnula@yahoo.com
Abstract:
The present study focuses on the physical and chemical stability of insulin under iontophoretic conditions using HPLC, SDS-PAGE, RIA and biological assay. Influence of pH, concentration of insulin, current strength and duration of current application on the stability of insulin was studied. Anodal iontophoresis at pH 7.4 caused more than 80% degradation of insulin, while the degradation was minimal at pH 3.6. The degradation was not influenced by insulin concentration, but increase in current strength above 0.75 mA/cm2 or application of current for 12 h (at 0.5 mA/cm2) led to 80 and 20% degradation respectively. All the samples showed biological activity comparable to intact insulin.