Generation of improved gas linear velocities in a comprehensive two-dimensional gas chromatography system
Peter Quinto Tranchida1, Alessandro Casilli, Paola Dugo
1Dipartimento Farmaco-Chimico, Facoltà di Farmacia, Università di Messina, viale Annunziata, 98168-Messina, Italy.
Abstract:
A comprehensive two-dimensional gas chromatography (GC x GC) system (for convenience defined as "split flow" GC x GC), which may be operated at improved gas linear velocities in both dimensions, has been developed. The setup is formed of an apolar 30 m x 0.25 mm i.d. column connected, by means of a Y press fit, to a detector-linked 1 m x 0.1 mm i.d. polar analytical column, which passes through the (cryogenic) modulator, and to a 0.3 m x 0.1 mm i.d. retention gap, which is connected to a manually operated split valve. The latter enables the regulation of gas flows through the second analytical column [e.g., 60:40 (FID) ratio, 50:50 ratio, 40:60 (FID) ratio, etc.], in order to generate the most appropriate gas linear velocity, which is related to each specific analysis. In the pre-sent investigation, two sets of traditional and split flow GC x GC analyses were carried out on a cod liver oil fatty acid methyl ester sample by using the same temperature programs [180-250 degrees C at (a) 3 degrees C/min and at (b) 1.3 degrees C/min] and at an average first-dimension linear velocity of approximately 35.0 cm/s; thus, primary column retention times (and therefore elution temperatures) were essentially maintained. The second-dimension linear velocity was calculated to be approximately 333 cm/s in the traditional applications, while it was split valve-regulated until the most appropriate values [(a) approximately 213 cm/s; (b) approximately 264 cm/s] were attained in the alternative applications. Substantial improvements were observed and measured in the chromatography along the y-axis, while the contour plot chemical class structure was maintained.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...